PCAP information from a 9920 device
is displayed in the XCO
interface.
About this task
A maximum of 25 PCAP files are supported for 9920.
Procedure
-
In the Navigation menu, select
Device
Inventory.
-
In the Devices page, click anywhere in the
required device row except the Actions column ()
to proceed to the device Overview page.
-
Select Capture Packets
from the Device Actions menu.
-
Select Configure Port
Capture or + (Enable PCAP) as
appropriate to start a new packet capture.
-
From the Packet Capture actions,
select Start.
-
In the Port field,
select a port on which to capture packets.
-
In the Direction field,
select the packet type:
- Ingress
(RX)
- Egress
(TX)
- Both
-
In the Packet Count
field, select the number of packets that you want to capture, from 1 to
8,000.
Packet capture stops when the
selected number of packets has been captured.
-
Select Add.
The capture configuration
for the selected port is displayed on the right.
-
Repeat step 5 through step 9 as needed to configure PCAPs for more ports.
PCAP configuration is supported
for a maximum of 10 ports for the selected device.
-
Select Save.
The Packet Capture page
displays running PCAPs and PCAP results.